PERMACOAT 6000 CHEMICAL RESISTANCE GUIDE

Days

Acetic Acid (Glacial) 03  
Acetic Acid (Glacial) 14*
Acetone 30
Acrylonitrile 30
Ammonium Hydroxide 30
Cyclohexane 30
Diethylbenzene 30
Ethyl Alcohol 30

Days

 
Ethylene Dichloride 30
Gasoline 30
Hydrochloric Acid 30
Methanol 30
Methyl Ethyl Ketone 30
Methylene Chloride 01
Methylene Chloride 14*
N-Methyl-2-Pyrrolidone 14

Days

 
Perchloroethylene 30
Sodium Hydroxide 30
Sulfuric Acid, 50% 30
Sulfuric Acid, 98% 03
Toluene 30
Trichloroethylene 30
Vinyl Acetate 30
Xylene 30

* To achieve these results, the product must be post-cured for 4 hours at 180-200oF before being placed into service.

No ratings beyond 30 days were issued for the PERMACOAT 6000 system since is it designed as a secondary containment system. For chemicals not listed and extended recommendations, contact ChemProof Polymers, Inc.